{"EGODeployment":[{"DEPLOYMENT_ID":716,"WIGOS_ID":"0-22000-5-6801588","DEPLOYMENT_START_DATE":20260323,"SUMMARY_REPORT":"This campaign involves the deployment of 2 Slocum gliders in Tampa Florida USA as part of the C-Streams project funded by NERC. Deployment took place in March 2026 from the RRS James Cook, with recovery planned for July 2026. ","BASE_STATION":"available in the raw data","EMAIL":"ric@liverpool.ac.uk","NAME":"Ric Williams","ACTIVE":1,"CAMPAIGNNAME":"C-Streams 3","PROJNAME":"C-Streams","PLATFORMMODEL":[{"MODEL_VERSION_ID":286,"MODEL_ID":841,"CATEGORY_TYPE":"platforms","DDESC":"Teledyne Webb Research Slocum G3S glider","PLATFORM_MAKER":"Teledyne Webb Research","UNIQUE_ID":"B7600029","PLATFORM_TYPE":"slocum","MODEL_NAME":"Teledyne Webb Research Slocum G3S glider","WMO_INST_TYPE":830}],"PLATFORMINSTANCE":[{"PLAT_INSTANCE_VERSION_ID":1542,"PLAT_INSTANCE_ID":1087,"DATA_TYPE":"EGO glider time-series data","GLIDER_SERIAL_NO":"unit_886","PLATFORM_CODE":"Chalky","GLIDER_OWNER":"NOCS","ICES_PLATFORM_CODE":"N\/A","WMO_PLATFORM_CODE":6801588,"PLATFORM_FAMILY":"open ocean glider"}],"SENSORLIST":[{"SENSORMODEL":[{"MODEL_VERSION_ID":263,"MODEL_ID":626,"SENSOR_MODEL":"WET Labs {Sea-Bird WETLabs} ECO Puck Triplet BB2FL-SLC scattering fluorescence sensor","SENSOR_MAKER":"WET Labs","MODEL_NAME":"WETLabs ECO Puck Triplet BB2FL-SLC scattering fluorescence sensor","INSTRUMENT_TYPE":"radiometers"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1697,"SENSOR_INSTANCE_ID":1256,"SENSOR_SERIAL_NO":6904,"SENSOR_NAME":"WET Labs ECO Puck Triplet BB2FL-SLC 6904"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPR01\/","PREFLABEL":"Concentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer","SDN_UOM_UM":"SDN:P06::UMMC","OG1_PARAMETER_URN":"CHLA","OG1_UOM_UM":"mg\/m3","VALID_MIN":0,"VALID_MAX":999,"FILLVALUE":-1},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/BVSFO532\/","PREFLABEL":"Volume scattering coefficient of electromagnetic radiation (532nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement","SDN_UOM_UM":"SDN:P06::PMSR","OG1_PARAMETER_URN":"BETA_BACKSCATTERING532","OG1_UOM_UM":"m-1.sr-1","VALID_MIN":0,"VALID_MAX":9,"FILLVALUE":-9},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/BVSFO700\/","PREFLABEL":"Volume scattering coefficient of electromagnetic radiation (700nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement","SDN_UOM_UM":"SDN:P06::PMSR","OG1_PARAMETER_URN":"BETA_BACKSCATTERING700","OG1_UOM_UM":"m-1.sr-1","VALID_MIN":0,"VALID_MAX":9,"FILLVALUE":-9}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":234,"MODEL_ID":448,"SENSOR_MODEL":"Aanderaa 4831 oxygen optode","SENSOR_MAKER":"Aanderaa","MODEL_NAME":"Oxygen optode 4831","INSTRUMENT_TYPE":"dissolved gas sensors"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1655,"SENSOR_INSTANCE_ID":1223,"SENSOR_SERIAL_NO":143,"SENSOR_NAME":"Aanderaa 4831 oxygen optode 143"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/OXYCOPVR\/","PREFLABEL":"Raw signal (voltage) of instrument output (red light wavelength excitation) by optode","SDN_UOM_UM":"SDN:P06::UUMV","VALID_MIN":0,"VALID_MAX":9999,"FILLVALUE":-1},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/OXYCPHAB\/","PREFLABEL":"Phase angle of blue light wavelength excitation {BPhase} by optode","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"BPHASE_DOXY","OG1_UOM_UM":"degree","VALID_MIN":0,"VALID_MAX":360,"FILLVALUE":-1},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/OXYCOPVB\/","PREFLABEL":"Raw signal (voltage) of instrument output (blue light wavelength excitation) by optode","SDN_UOM_UM":"SDN:P06::UUMV","VALID_MIN":0,"VALID_MAX":9999,"FILLVALUE":-1},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/OXYSOP01\/","PREFLABEL":"Saturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by in-situ oxygen optode and computation from concentration","SDN_UOM_UM":"SDN:P06::UPCT","OG1_PARAMETER_URN":"OXYSAT_DOXY","OG1_UOM_UM":"%","VALID_MIN":0,"VALID_MAX":180,"FILLVALUE":-1},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/OXYCPHAC\/","PREFLABEL":"Phase angle of D phase by optode","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"DPHASE_DOXY","OG1_UOM_UM":"degree","VALID_MIN":0,"VALID_MAX":360,"FILLVALUE":-1,"SOURCENAME":"sci_oxy4_calphase"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/DOXYAAOP\/","PREFLABEL":"Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by optode","SDN_UOM_UM":"SDN:P06::UPOX","OG1_PARAMETER_URN":"MOLAR_DOXY","OG1_UOM_UM":"micromole\/l","VALID_MIN":0,"VALID_MAX":600,"FILLVALUE":-1,"SOURCENAME":"sci_oxy4_oxygen"}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":288,"MODEL_ID":881,"SENSOR_MODEL":"Teledyne Webb Research Slocum G3S Glider Navigation data logger","SENSOR_MAKER":"Teledyne Webb Research","MODEL_NAME":"Teledyne Webb Research Slocum G3S Glider Navigation data logger","INSTRUMENT_TYPE":"data loggers"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1548,"SENSOR_INSTANCE_ID":1093,"SENSOR_SERIAL_NO":"unit_886","SENSOR_NAME":"Slocum G3S Glider data logger unit_886"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ADEPZZ01\/","PREFLABEL":"Depth (spatial coordinate) relative to water surface in the water body","SDN_UOM_UM":"SDN:P06::ULAA","OG1_PARAMETER_URN":"GLIDER_DEPTH","OG1_UOM_UM":"m","VALID_MIN":0,"VALID_MAX":9999,"FILLVALUE":-1,"SOURCENAME":"m_depth"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PTCHEI01\/","PREFLABEL":"Orientation (pitch) of measurement platform by inclinometer","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"GLIDER_PITCH","OG1_UOM_UM":"deg","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_pitch"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ROLLEI01\/","PREFLABEL":"Orientation (roll) of measurement platform by inclinometer","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"GLIDER_ROLL","OG1_UOM_UM":"deg","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_roll"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/VOLCHA01\/","PREFLABEL":"Volume change of buoyancy control oil","SDN_UOM_UM":"SDN:P06::VVCC","OG1_PARAMETER_URN":"OIL_VOL","OG1_UOM_UM":"cm^3","VALID_MIN":-3000,"VALID_MAX":3000,"FILLVALUE":-9999,"SOURCENAME":"m_de_oil_vol"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCEWCD01\/","PREFLABEL":"Eastward velocity of water current (Lagrangian measurement) in the water body by dead reckoning and correction for surface drift","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATER_VELOC_FINAL_U","OG1_UOM_UM":"m\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_final_water_vx"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCNSCD01\/","PREFLABEL":"Northward velocity of water current (Lagrangian measurement) in the water body by dead reckoning and correction for surface drift","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATER_VELOC_FINAL_V","OG1_UOM_UM":"m\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_final_water_vy"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PRESPR02\/","PREFLABEL":"Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor (second sensor) and correction to read zero at sea level","SDN_UOM_UM":"SDN:P06::UPDB","OG1_PARAMETER_URN":"PRES_ENG","OG1_UOM_UM":"dbar","VALID_MIN":0,"VALID_MAX":15000,"FILLVALUE":-9999,"SOURCENAME":"m_pressure"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/HEADCMMG\/","PREFLABEL":"Orientation (horizontal) of measurement platform relative to magnetic north {heading} by compass","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"GLIDER_HEADING","OG1_UOM_UM":"deg","VALID_MIN":0,"VALID_MAX":360,"FILLVALUE":-1,"SOURCENAME":"m_heading"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCEWZZ01\/","PREFLABEL":"Eastward velocity of water current in the water body","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATERCURRENTS_U","OG1_UOM_UM":"cm\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_water_vx"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/AHSFZZ01\/","PREFLABEL":"Height (spatial coordinate) relative to bed surface in the water body","SDN_UOM_UM":"SDN:P06::ULAA","OG1_PARAMETER_URN":"ALTITUDE","OG1_UOM_UM":"m","VALID_MIN":0,"VALID_MAX":12000,"FILLVALUE":-1,"SOURCENAME":"m_altitude"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALATZZ01\/","PREFLABEL":"Latitude north","SDN_UOM_UM":"SDN:P06::DEGN","OG1_PARAMETER_URN":"LATITUDE","OG1_UOM_UM":"degree_north","VALID_MIN":-90,"VALID_MAX":90,"FILLVALUE":-99,"SOURCENAME":"m_lat"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALATGP01\/","PREFLABEL":"Latitude north relative to WGS84 by unspecified GPS system","SDN_UOM_UM":"SDN:P06::DEGN","OG1_PARAMETER_URN":"LATITUDE_GPS","OG1_UOM_UM":"degree_north","VALID_MIN":-90,"VALID_MAX":90,"FILLVALUE":-99,"SOURCENAME":"m_gps_lat"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALONZZ01\/","PREFLABEL":"Longitude east","SDN_UOM_UM":"SDN:P06::DEGE","OG1_PARAMETER_URN":"LONGITUDE","OG1_UOM_UM":"degree_east","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_lon"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALONGP01\/","PREFLABEL":"Longitude east relative to WGS84 by unspecified GPS system","SDN_UOM_UM":"SDN:P06::DEGE","OG1_PARAMETER_URN":"LONGITUDE_GPS","OG1_UOM_UM":"degree_east","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_gps_lon"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCNSZZ01\/","PREFLABEL":"Northward velocity of water current in the water body","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATERCURRENTS_V","OG1_UOM_UM":"cm\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_water_vy"}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":301,"MODEL_ID":1101,"SENSOR_MODEL":"Rockland Scientific MicroRider-1000 turbulence microstructure profiler","SENSOR_MAKER":"Rockland Scientific","MODEL_NAME":"Rockland Scientific MicroRider-1000 turbulence microstructure profiler","INSTRUMENT_TYPE":"microstructure sensors"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1737,"SENSOR_INSTANCE_ID":1301,"SENSOR_SERIAL_NO":528,"SENSOR_NAME":"Rockland Scientific MicroRider-1000 turbulence microstructure profiler 528"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTCPTT\/","PREFLABEL":"Raw signal (counts) mean of instrument output by in-situ thermistor","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_MEAN_TURB_THERMISTOR","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c4_avg"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTSDCP\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by in-situ thermistor","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_THERMISTOR","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c5_std"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTCPT2\/","PREFLABEL":"Raw signal (counts) mean of instrument output by in-situ thermistor (second sensor)","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_MEAN_TURB_THERMISTOR_2","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c6_avg"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTSDC2\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by in-situ thermistor (second sensor)","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_THERMISTOR_2","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c7_std"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/EPSVTBPT\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by turbulence profiler shear sensor","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_SHEAR","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c8_std"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/EPSVTBP2\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by turbulence profiler shear sensor (second sensor)","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_SHEAR_2","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c9_std"}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":287,"MODEL_ID":861,"SENSOR_MODEL":"RBR Legato3 CTD","SENSOR_MAKER":"RBR","MODEL_NAME":"RBR Legato3 CTD","INSTRUMENT_TYPE":"CTD"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1738,"SENSOR_INSTANCE_ID":1090,"SENSOR_SERIAL_NO":204550,"SENSOR_NAME":"RBR Legato3 CTD 204550"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CNDCST01\/","PREFLABEL":"Electrical conductivity of the water body by CTD","SDN_UOM_UM":"SDN:P06::UECA","OG1_PARAMETER_URN":"CNDC","OG1_UOM_UM":"mhos\/m","VALID_MIN":0,"VALID_MAX":6.5,"FILLVALUE":-1,"SOURCENAME":"sci_water_cond"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PRESPR01\/","PREFLABEL":"Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level","SDN_UOM_UM":"SDN:P06::UPDB","OG1_PARAMETER_URN":"PRES","OG1_UOM_UM":"decibar","VALID_MIN":0,"VALID_MAX":15000,"FILLVALUE":-99,"SOURCENAME":"sci_water_pressure"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TEMPST01\/","PREFLABEL":"Temperature of the water body by CTD or STD","SDN_UOM_UM":"SDN:P06::UPAA","OG1_PARAMETER_URN":"TEMP","OG1_UOM_UM":"degree_Celsius","VALID_MIN":-3,"VALID_MAX":35,"FILLVALUE":-9,"SOURCENAME":"sci_water_temp"}]}]}]}