{"EGODeployment":[{"DEPLOYMENT_ID":679,"WIGOS_ID":"0-22000-4-6801588","DEPLOYMENT_START_DATE":20250323,"SUMMARY_REPORT":"This campaign involved the deployment of two G3 slocum gliders near the Mid-Atlantic Ridge in the South Atlantic, as part of the CarTRidge project funded by NERC. The gliders were deployed in February 2025 and recovered in March 2025 by RRS James Cook JC275.","BASE_STATION":"available in the raw data","EMAIL":"jonathan.sharples@liverpool.ac.uk","NAME":"Jonathan Sharples","ACTIVE":0,"CAMPAIGNNAME":"CarTRidge","PROJNAME":"CarTRidge","PLATFORMMODEL":[{"MODEL_VERSION_ID":286,"MODEL_ID":841,"CATEGORY_TYPE":"platforms","DDESC":"Teledyne Webb Research Slocum G3S glider","PLATFORM_MAKER":"Teledyne Webb Research","UNIQUE_ID":"B7600029","PLATFORM_TYPE":"slocum","MODEL_NAME":"Teledyne Webb Research Slocum G3S glider","WMO_INST_TYPE":830}],"PLATFORMINSTANCE":[{"PLAT_INSTANCE_VERSION_ID":1542,"PLAT_INSTANCE_ID":1087,"DATA_TYPE":"EGO glider time-series data","GLIDER_SERIAL_NO":"unit_886","PLATFORM_CODE":"Chalky","GLIDER_OWNER":"NOCS","ICES_PLATFORM_CODE":"N\/A","WMO_PLATFORM_CODE":6801588,"PLATFORM_FAMILY":"open ocean glider"}],"SENSORLIST":[{"SENSORMODEL":[{"MODEL_VERSION_ID":287,"MODEL_ID":861,"SENSOR_MODEL":"RBR Legato3 CTD","SENSOR_MAKER":"RBR","MODEL_NAME":"RBR Legato3 CTD","INSTRUMENT_TYPE":"CTD"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1696,"SENSOR_INSTANCE_ID":1092,"SENSOR_SERIAL_NO":207225,"SENSOR_NAME":"RBR Legato3 CTD 207225"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CNDCST01\/","PREFLABEL":"Electrical conductivity of the water body by CTD","SDN_UOM_UM":"SDN:P06::UECA","OG1_PARAMETER_URN":"CNDC","OG1_UOM_UM":"mhos\/m","VALID_MIN":0,"VALID_MAX":6.5,"FILLVALUE":-1,"SOURCENAME":"sci_water_cond"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PRESPR01\/","PREFLABEL":"Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level","SDN_UOM_UM":"SDN:P06::UPDB","OG1_PARAMETER_URN":"PRES","OG1_UOM_UM":"decibar","VALID_MIN":0,"VALID_MAX":15000,"FILLVALUE":-99,"SOURCENAME":"sci_water_pressure"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TEMPST01\/","PREFLABEL":"Temperature of the water body by CTD or STD","SDN_UOM_UM":"SDN:P06::UPAA","OG1_PARAMETER_URN":"TEMP","OG1_UOM_UM":"degree_Celsius","VALID_MIN":-3,"VALID_MAX":35,"FILLVALUE":-9,"SOURCENAME":"sci_water_temp"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ELTMEP01\/","PREFLABEL":"Elapsed time relative to 1970-01-01T00:00:00Z","SDN_UOM_UM":"SDN:P06::UTBB","OG1_PARAMETER_URN":"TIME","OG1_UOM_UM":"s","VALID_MIN":0,"VALID_MAX":9000000000,"FILLVALUE":-1}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":263,"MODEL_ID":626,"SENSOR_MODEL":"WET Labs {Sea-Bird WETLabs} ECO Puck Triplet BB2FL-SLC scattering fluorescence sensor","SENSOR_MAKER":"WET Labs","MODEL_NAME":"WETLabs ECO Puck Triplet BB2FL-SLC scattering fluorescence sensor","INSTRUMENT_TYPE":"radiometers"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1697,"SENSOR_INSTANCE_ID":1256,"SENSOR_SERIAL_NO":6904,"SENSOR_NAME":"WET Labs ECO Puck Triplet BB2FL-SLC 6904"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/CPHLPR01\/","PREFLABEL":"Concentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer","SDN_UOM_UM":"SDN:P06::UMMC","OG1_PARAMETER_URN":"CHLA","OG1_UOM_UM":"mg\/m3","VALID_MIN":0,"VALID_MAX":999,"FILLVALUE":-1},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/BVSFO532\/","PREFLABEL":"Volume scattering coefficient of electromagnetic radiation (532nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement","SDN_UOM_UM":"SDN:P06::PMSR","OG1_PARAMETER_URN":"BETA_BACKSCATTERING532","OG1_UOM_UM":"m-1.sr-1","VALID_MIN":0,"VALID_MAX":9,"FILLVALUE":-9},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/BVSFO700\/","PREFLABEL":"Volume scattering coefficient of electromagnetic radiation (700nm wavelength) {Beta} in the water body by in-situ optical backscatter measurement","SDN_UOM_UM":"SDN:P06::PMSR","OG1_PARAMETER_URN":"BETA_BACKSCATTERING700","OG1_UOM_UM":"m-1.sr-1","VALID_MIN":0,"VALID_MAX":9,"FILLVALUE":-9}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":234,"MODEL_ID":448,"SENSOR_MODEL":"Aanderaa 4831 oxygen optode","SENSOR_MAKER":"Aanderaa","MODEL_NAME":"Oxygen optode 4831","INSTRUMENT_TYPE":"dissolved gas sensors"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1080,"SENSOR_INSTANCE_ID":623,"SENSOR_SERIAL_NO":120,"SENSOR_NAME":"Aanderaa 4831 oxygen optode 120"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/OXYCPHAC\/","PREFLABEL":"Phase angle of D phase by optode","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"DPHASE_DOXY","OG1_UOM_UM":"degree","VALID_MIN":0,"VALID_MAX":360,"FILLVALUE":-1,"SOURCENAME":"sci_oxy4_calphase"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/DOXYAAOP\/","PREFLABEL":"Concentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by optode","SDN_UOM_UM":"SDN:P06::UPOX","OG1_PARAMETER_URN":"MOLAR_DOXY","OG1_UOM_UM":"micromole\/l","VALID_MIN":0,"VALID_MAX":600,"FILLVALUE":-1,"SOURCENAME":"sci_oxy4_oxygen"}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":301,"MODEL_ID":1101,"SENSOR_MODEL":"Rockland Scientific MicroRider-1000 turbulence microstructure profiler","SENSOR_MAKER":"Rockland Scientific","MODEL_NAME":"Rockland Scientific MicroRider-1000 turbulence microstructure profiler","INSTRUMENT_TYPE":"microstructure sensors"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1687,"SENSOR_INSTANCE_ID":1255,"SENSOR_SERIAL_NO":105,"SENSOR_NAME":"MicroRider-1000 microstructure profiler 105"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTCPTT\/","PREFLABEL":"Raw signal (counts) mean of instrument output by in-situ thermistor","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_MEAN_TURB_THERMISTOR","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c4_avg"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTSDCP\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by in-situ thermistor","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_THERMISTOR","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c5_std"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTCPT2\/","PREFLABEL":"Raw signal (counts) mean of instrument output by in-situ thermistor (second sensor)","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_MEAN_TURB_THERMISTOR_2","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c6_avg"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/TCNTSDC2\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by in-situ thermistor (second sensor)","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_THERMISTOR_2","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c7_std"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/EPSVTBPT\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by turbulence profiler shear sensor","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_SHEAR","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c8_std"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/EPSVTBP2\/","PREFLABEL":"Raw signal (counts) standard deviation of instrument output by turbulence profiler shear sensor (second sensor)","SDN_UOM_UM":"SDN:P06::UUUU","OG1_PARAMETER_URN":"RAW_STDEV_TURB_SHEAR_2","OG1_UOM_UM":"Dmnless","VALID_MIN":-9000,"VALID_MAX":99999999,"FILLVALUE":-9999,"SOURCENAME":"sci_microrider_c9_std"}]},{"SENSORMODEL":[{"MODEL_VERSION_ID":288,"MODEL_ID":881,"SENSOR_MODEL":"Teledyne Webb Research Slocum G3S Glider Navigation data logger","SENSOR_MAKER":"Teledyne Webb Research","MODEL_NAME":"Teledyne Webb Research Slocum G3S Glider Navigation data logger","INSTRUMENT_TYPE":"data loggers"}],"SENSORINSTANCE":[{"SENSOR_INSTANCE_VERSION_ID":1548,"SENSOR_INSTANCE_ID":1093,"SENSOR_SERIAL_NO":"unit_886","SENSOR_NAME":"Slocum G3S Glider data logger unit_886"}],"PARAMETERLIST":[{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ADEPZZ01\/","PREFLABEL":"Depth (spatial coordinate) relative to water surface in the water body","SDN_UOM_UM":"SDN:P06::ULAA","OG1_PARAMETER_URN":"GLIDER_DEPTH","OG1_UOM_UM":"m","VALID_MIN":0,"VALID_MAX":9999,"FILLVALUE":-1,"SOURCENAME":"m_depth"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PTCHEI01\/","PREFLABEL":"Orientation (pitch) of measurement platform by inclinometer","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"GLIDER_PITCH","OG1_UOM_UM":"deg","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_pitch"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ROLLEI01\/","PREFLABEL":"Orientation (roll) of measurement platform by inclinometer","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"GLIDER_ROLL","OG1_UOM_UM":"deg","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_roll"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/VOLCHA01\/","PREFLABEL":"Volume change of buoyancy control oil","SDN_UOM_UM":"SDN:P06::VVCC","OG1_PARAMETER_URN":"OIL_VOL","OG1_UOM_UM":"cm^3","VALID_MIN":-3000,"VALID_MAX":3000,"FILLVALUE":-9999,"SOURCENAME":"m_de_oil_vol"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCEWCD01\/","PREFLABEL":"Eastward velocity of water current (Lagrangian measurement) in the water body by dead reckoning and correction for surface drift","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATER_VELOC_FINAL_U","OG1_UOM_UM":"m\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_final_water_vx"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCNSCD01\/","PREFLABEL":"Northward velocity of water current (Lagrangian measurement) in the water body by dead reckoning and correction for surface drift","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATER_VELOC_FINAL_V","OG1_UOM_UM":"m\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_final_water_vy"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/PRESPR02\/","PREFLABEL":"Pressure (spatial coordinate) exerted by the water body by profiling pressure sensor (second sensor) and correction to read zero at sea level","SDN_UOM_UM":"SDN:P06::UPDB","OG1_PARAMETER_URN":"PRES_ENG","OG1_UOM_UM":"dbar","VALID_MIN":0,"VALID_MAX":15000,"FILLVALUE":-9999,"SOURCENAME":"m_pressure"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/HEADCMMG\/","PREFLABEL":"Orientation (horizontal) of measurement platform relative to magnetic north {heading} by compass","SDN_UOM_UM":"SDN:P06::UAAA","OG1_PARAMETER_URN":"GLIDER_HEADING","OG1_UOM_UM":"deg","VALID_MIN":0,"VALID_MAX":360,"FILLVALUE":-1,"SOURCENAME":"m_heading"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCEWZZ01\/","PREFLABEL":"Eastward velocity of water current in the water body","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATERCURRENTS_U","OG1_UOM_UM":"cm\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_water_vx"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/AHSFZZ01\/","PREFLABEL":"Height (spatial coordinate) relative to bed surface in the water body","SDN_UOM_UM":"SDN:P06::ULAA","OG1_PARAMETER_URN":"ALTITUDE","OG1_UOM_UM":"m","VALID_MIN":0,"VALID_MAX":12000,"FILLVALUE":-1,"SOURCENAME":"m_altitude"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALATZZ01\/","PREFLABEL":"Latitude north","SDN_UOM_UM":"SDN:P06::DEGN","OG1_PARAMETER_URN":"LATITUDE","OG1_UOM_UM":"degree_north","VALID_MIN":-90,"VALID_MAX":90,"FILLVALUE":-99,"SOURCENAME":"m_lat"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALATGP01\/","PREFLABEL":"Latitude north relative to WGS84 by unspecified GPS system","SDN_UOM_UM":"SDN:P06::DEGN","OG1_PARAMETER_URN":"LATITUDE_GPS","OG1_UOM_UM":"degree_north","VALID_MIN":-90,"VALID_MAX":90,"FILLVALUE":-99,"SOURCENAME":"m_gps_lat"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALONZZ01\/","PREFLABEL":"Longitude east","SDN_UOM_UM":"SDN:P06::DEGE","OG1_PARAMETER_URN":"LONGITUDE","OG1_UOM_UM":"degree_east","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_lon"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/ALONGP01\/","PREFLABEL":"Longitude east relative to WGS84 by unspecified GPS system","SDN_UOM_UM":"SDN:P06::DEGE","OG1_PARAMETER_URN":"LONGITUDE_GPS","OG1_UOM_UM":"degree_east","VALID_MIN":-180,"VALID_MAX":180,"FILLVALUE":-999,"SOURCENAME":"m_gps_lon"},{"OBJECTTYPE":"parameter","SDN_PARAMETER_URN":"http:\/\/vocab.nerc.ac.uk\/collection\/P01\/current\/LCNSZZ01\/","PREFLABEL":"Northward velocity of water current in the water body","SDN_UOM_UM":"SDN:P06::UVAA","OG1_PARAMETER_URN":"WATERCURRENTS_V","OG1_UOM_UM":"cm\/s","VALID_MIN":-500,"VALID_MAX":500,"FILLVALUE":-9999,"SOURCENAME":"m_water_vy"}]}]}]}